      Deadweight Tester Accessories

      Fluke Calibration provides the complete solution for pressure calibration using a deadweight tester, including accessories for test media separation, dirt / moisture traps, dial gauge pointer removers, angle adapters, and two gauge test stands.

      P5521 and P5522 Liquid-to-Liquid Separators

      P5500 Adapters, Separators and Dirt/Moisture Traps

      These liquid-to-liquid separators connect directly to the test port of a hydraulic deadweight tester or comparison test pump. A flexible diaphragm separates the fluids, protecting the calibrator from contamination, and allows calibration of the device in its specific working fluid.

      • P5521-For pressures to 10,000 psi (700 bar)
      • P5522-For pressures to 7,000 psi (480 bar) for Skydrol or other aggressive fluids

      P5523 Liquid-to-Gas Media Separator

      P5500 Adapters, Separators and Dirt/Moisture Traps

      Pressure range 0 to 3,000 psi (210 bar)

      For high pressure pneumatic calibrations this unit interfaces with hydraulic deadweight testers providing a rateless liquid-to-gas separation. Driven by a pneumatic pressure source (nitrogen bottle) and controlled by needle valves, high pressure gas is balanced against the liquid in a hydraulic deadweight tester through a series of fluid traps.

      * Note---since fluid mist may be transferred during operation we do not recommend this device for oxygen safe instruments using an oil operated deadweight tester

      P5531 Dirt / Moisture Trap

      P5500 Adapters, Separators and Dirt/Moisture Traps

      Pressure range 0 to 500 psi (35 bar)

      Dirt / moisture traps provide an effective barrier against the transfer of moisture and dirt from an instrument under test to the sensitive piston/cylinder assembly of a pneumatic deadweight tester. Unexpected particle contamination or fluid inside the device under test will be prevented from entering the deadweight system, avoiding downtime for maintenance or repair. Designed for operation in the vertical position these traps are simple to dismantle and easy to clean.

      Designed to mount directly on the deadweight tester and featuring an acrylic chamber for visibility of contaminates this unit utilizes the standard test port adapters for easy instrument connections.

      P5532 Dirt / Moisture Trap

      P5500 Adapters, Separators and Dirt/Moisture Traps

      Pressure range 0 to 3,000 psi (210 bar)

      Dirt / moisture traps provide an effective barrier against the transfer of moisture and dirt from an instrument under test to the sensitive piston/cylinder assembly of a pneumatic deadweight tester. Unexpected particle contamination or fluid inside the device under test will be prevented from entering the deadweight system, avoiding downtime for maintenance or repair. Designed for operation in the vertical position these traps are simple to dismantle and easy to clean.

      This high pressure version is provided with an aluminum central chamber for safety and utilizes the standard test port adapters.

      P5540, P5541, and P5542 Adapter Sets

      P5500 Adapters, Separators and Dirt/Moisture Traps

      These thread adapters come in metric, BSP & NPT sizes to help you make connections with Fluke P5500 series hydraulic and pneumatic comparison test pumps, media separators & accessories.

      P5540 Metric

      M14 x 1.5, M20 x 1.5, 1/8 and 1/4 BSP

      P5541 BSP

      1/8, 1/4, 3/8 and 1/2 BSP

      P5542 NPT

      1/8, 1/4, 3/8 and 1/2 NPT

      P5543 Angle Adapter

      P5500 Adapters, Separators and Dirt/Moisture Traps

      To calibrate gauges with the pressure connection on the rear (for example, panel mount gauges) in their correct operating position, an angle adaptor should be used. The angle adapter uses the standard gauge adapters and positions the gauges at 90º. The maximum working pressure of this unit is 10,000 psi (700 bar).

      P5544 Two Gauge Stand

      P5500 Adapters, Separators and Dirt/Moisture Traps

      This adapter mounts directly to the test port of the calibrator and allows for the calibration of two instruments at the same time, or the connection of a reference test instrument. Maximum working pressure is 10,000 psi (700 bar).

      P5551 Pointer Remover / Punch

      P5500 Adapters, Separators and Dirt/Moisture Traps

      This tool is designed to quickly remove and consistently refit the pointer of a pressure gauge.

      Specifications: P5500 Adapters, Separators and Dirt/Moisture Traps

      P5521 and P5522 Liquid-to-Liquid Separators

      Specifications
      Pressure RangeP5521: 0 to 10,000 psi (700 bar)
      P5522: 0 to 7,000 psi (480 bar) for Skydrol and other aggressive fluids
      Instrument Size (W x H)4 x 6 in (100 x 150 mm)
      Instrument Weight7.5 lb (3.5 kg)
      Test Port AdapterUses adapters supplied with calibrator
      Calibrator Connection3/8 BSP male (mating adapter supplied)
      Body MaterialAluminum bronze
      Diaphragm5521- Viton® 5522-Ethylene Propylene
      Reservoir MaterialHard-anodized aluminum

      P5523 Liquid-to-Gas Media Separator

      Specifications
      Instrument Size (W x D x H)17.5 x 12 x 8.5 in ( 440 x 300 x 215 mm)
      Instrument Weight24 lb (11 kg)
      Test Port Adapters2 sets, 1/8, 1/4, 3/8 and 1/2 NPT or BSP
      Gas Supply Connection1/4 NPT female

      P5531 Dirt / Moisture Trap

      Specifications
      Pressure Range0 to 500 psi (35 bar)
      Body MaterialStainless steel
      Chamber MaterialAcrylic
      O-RingsNitrile
      Test Port ConnectionAs supplied with calibrator
      Deadweight Connection3/8 BSP male (mating adapter supplied

      P5532 Dirt / Moisture Trap

      Specifications
      Body MaterialStainless steel
      Chamber MaterialAluminum
      O-RingsNitrile
      Test Port ConnectionAs supplied with calibrator
      Deadweight Connection3/8 BSP male (mating adapter supplied)

      P5543 Angle Adapter

      Specifications
      Body materialsStainless steel
      O-RingsNitrile
      Test Port AdaptersAs supplied with calibrator
      Calibrator Connection3/8 BSP male (mating adapter supplied)

      P5544 Two Gauge Stand

      Specifications
      Body MaterialBrass and Stainless steel
      O-RingsNitrile
      Test Port Adapters1 set, 1/8, 1/4, 3/8 and 1/2 NPT or BSP and adapters supplied with calibrator
      Calibrator Test Connection1/2 BSP male (mating adapter supplied)

      Models: P5500 Adapters, Separators and Dirt/Moisture Traps

      P5521
      P5521 Liquid to Liquid Separators
      Pressure Range 0 to 10,000 psi (700 bar)

      Find a distributor
      P5522
      P5522 Liquid-to-Liquid Separator
      Pressure Range 0 to 7,000 psi (480 bar)

      Find a distributor
      P5523
      P5523 Liquid-to-Gas Media Separator
      Pressure range 0 to 3,000 psi (210 bar)

      Find a distributor

      For high pressure pneumatic calibrations this unit interfaces with hydraulic deadweight testers providing a rateless liquid-to-gas separation. Driven by a pneumatic pressure source (nitrogen bottle) and controlled by needle valves, high pressure gas is balanced against the liquid in a hydraulic deadweight tester through a series of fluid traps.

      * Note---since fluid mist may be transferred during operation we do not recommend this device for oxygen safe instruments using an oil operated deadweight tester.

      P5532

      Dirt/Moisture Trap


      Find a distributor
      NPT
      Adapter Set

      Find a distributor
      P5541
      P5541 BSP Adapter Sets

      Find a distributor
      • NPT: Adapter Set
      • P5540: Metric Adapter Set
      • P5541: BSP Adapter Set
      P5540
      P5540 Metric Adapter Sets

      Find a distributor
      • NPT: Adapter Set
      • P5540: Metric Adapter Set
      • P5541: BSP Adapter Set
      P5543
      P5543 Angle Adapter

      Find a distributor
      P5544

      P5544 Two Gauge Stand


      Find a distributor
      P5551
      P5551 Pointer Remover/Punch

      Find a distributor
      • bvseo_sdk, p_sdk, 3.2.1
      • CLOUD, getContent, 22.85ms
      • QUESTIONS, PRODUCT
      • bvseo-msg: HTTP status code of 404 was returned;
      • bvseo_sdk, p_sdk, 3.2.1
      • CLOUD, getReviews, 21.82ms
      • REVIEWS, PRODUCT
      • bvseo-msg: HTTP status code of 404 was returned;
      Please enable cookies to view product reviews.
      Chat with ourFluke assistant
      Clear Chat

      Hi, I'm your virtual assistant, I will do my very best to help you navigate all things Fluke related. You can ask me anything!

      I'm new and might make a few mistakes. For safe use of Fluke tools, refer to the product manuals, safety sheets, and your company's safety requirements. To speak with a person, visit our Contact Us or Talk to Sales page. For information on how we handle personal data, see our Privacy Policy