TITLE | VER | USE WITH | DOCUMENTS |
COMPASS® for Pressure™ |
5.2.10 2024.05.21 |
FPG8601, PG7000, PPC2, PPC2+, PPC2 AF, PPC3, PPC4, PPCH, PPCK, PPCK+, RPM3, RPM4, 7050, 7052, 7250, 7252, 7350, 7615, 7750, 7010, 7215, 2465, 2456, 2271A, 6270A, 8270A, 8370A, Third party piston gauges, pressure controllers and T&M hardware. |
Example Setup Database A COMPASS example greatly simplifies the requirements of adding a new device to the COMPASS. |
Description When downloaded, this file can be run to install COMPASS for Pressure Basic and COMPASS for Pressure Enhanced. |
|||
Summary COMPASS® for Pressure is a universal platform for all of your pressure calibration software needs. From piston gauges calibrating individual devices in the cal lab to transfer standards characterizing racks of sensors in production, COMPASS provides an off-the-shelf software tool to maximize the automation of your calibration and testing processes. COMPASS for Pressure integrates calibration functions with pressure specific dependencies that are missing from more generic software packages. Thanks to COMPASS's flexible data output options, the data it collects is easily imported into higher level applications such as Fluke MET/TEAM®. This allows the benefits of COMPASS's specialization in pressure calibration to be enjoyed while maintaining the link to your organization's overall calibration management system. |
Version 5 Releases | ||
5.2.10 (2024.05.21) | ||
FIX | COM-149 | For new installations, set the default state of "Clear IEEE interface before sending a new command" to checked on the Options | Interface tab. |
FIX | COM-200 | Resolved an issue with manual tests where the "Select Units of Measure" selection didn't carry through to the remaining setup screens and the 6270A unit. |
FIX | COM-210 | Resolved an issue with test definitions where the "Select Units of Measure" selection didn't carry through to the remaining setup screens and the 6270A unit. |
FIX | COM-220 | Resolved some GPIB communications issues |
FIX | COM-230 | Resolved an issue where networked workstations were not retaining their previous settings. |
FIX | COM-240 | Compass now records the Q-RPT information to the data file. |
FIX | COM-250 | Resolved an issue where the RS-232 settings and serial number wasn't getting remembered from the previous test setup. |
FIX | COM-260 | At the end of a test, the 2271A, 6270A, 8270A and 8370A have their safety limits reset to the defaults. |
FIX | COM-319 | Resolved an issue where the manual entry prompt was in the incorrect units. |
5.1.0 (2021.05.14) | ||
FIX | COM-3 | "Auto Fill" test points sometimes has additional resolution after decimal. |
FIX | COM-4 | Additional digit for local gravity from piston gauge base no longer written to data file. |
FIX | COM-6 | Pressure controller no longer controlling during leak test with PG7000/PG9000 reference. |
FIX | COM-7 | Change 2271A/6270A/8270A/8370A ready tolerance to the specified pressure unit instead of "% of range" to prevent incorrect ready tolerance value. |
FIX | COM-8 | Some pressure units in COMPASS for Pressure (for example inHg@60F) would result in an error during initialization. |
FIX | COM-10 | Use % Span instead of % FS for tolerance when DUT max pressure is 0 (zero). |
FIX | COM-12 | Remove access to 2465 Autofloat controller and 2456 PG Monitor calibration coefficients. |
FIX | COM-14 | PA calculation corrected when test is run with AutoZero off and non-zero zOffset (AutoZero) value. |
FIX | COM-16 | zOffset (AutoZero) value is now correctly sent to device by report templates "RPTCalibration.tpl" and "RPTCalibration_As Left.tpl". |
FIX | COM-19 | Pressure ranges for PM500 modules with xx70A Autodetect pressure controllers. |
FIX | COM-20 | Improved Safety Limits for xx70A Autodetect pressure controllers with PM Modules. |
FIX | COM-21 | "Reference ID" and "Reference ID Info" fields added to "fields to log" list in [Tools], |
FIX | COM-23 | Ref_COM2 and DUT_COM2 features removed. |
FIX | COM-24 | Stability setting for xx70A pressure controllers now set in unit/min instead of unit/sec. |
FIX | COM-31 | Additional resolution when using 7250xi pressure controller. |
FIX | COM-39 | Actual Pressure (UserDefined2) and Actual Temperature (User Defined1) fields now shown in help file. |
FIX | COM-41 | With xx70A pressure controllers, if there are no modules detected, then the error message box now reads "There were no pressure modules detected". |
ADD | COM-45 | Tests, macros and templates added to calibrate and adjust PM Modules in pressure controller. |
FIX | COM-46 | Do not skip target pressure setting of zero (0) when in absolute mode for 725x and xx70A Autodetect pressure controllers. |
FIX | COM-47 | Per-point custom dwell time now applicable only to the single point. |
FIX | COM-48 | Error 113 no longer appears on xx70A pressure controller when [Tools],<Option>,< Initialize test>, "Load Calibration info for AutoDetect Devices" checkbox is checked and test in in gauge mode. |
FIX | COM-49 | Set head to xx70A pressure controllers correctly when controller is in cm units. |
FIX | COM-50 | Limit xx70A pressure controller fluid head selections to air and nitrogen. |
FIX | COM-52 | Test will now run if % DUT Span and % DUT FS are selected on different tabs of the test. |
FIX | COM-53 | COMPASS Report Editor, Data Selector interface now supports ordering of files by use of the [Shift]+"Up arrow" key. |
FIX | COM-64 | "Reference ID" and "Reference ID Info" fields added to "fields to log" list in [Tools], <Options>, <Data in File> |
FIX | COM-82 | Multiplexor channels being set and read correctly. |
5.0.50 (2018.11.01) | ||
FIX | CPP-42 | Help file, improved description for hold limit in pre-test tab |
CHANGE | CPP-49 | Help file, update PG7000 run window |
FIX | CPP-50 | "Medium" during test initialization now changes 7615 setting |
CHANGE | CPP-51 | Help file, improved Ruska PC and mass set import instructions |
CHANGE | CPP-52 | Help file, Improved CalTool for PG7000 information |
CHANGE | CPP-77 | Improved Safety Limits for Autodetect 6270A |
FIX | CPP-93 | Autodetect 6270A recognizes BG measurement modules |
FIX | CPP-94 | Networked database recognizes multi-user license |
FIX | CPP-98 | Hold limit for "% DUT FS" was calculated based on "% DUT Span" |
FIX | CPP-99 | Leak Test feature always stopped test |
FIX | CPP-100 | Plot/graph selection was not retained test to test |
FIX | CPP-102 | During leak test status bar showed "Dwell Time Remaining" |
FIX | CPP-111 | Get Command macros only ran once |
FIX | CPP-113 | Exercise max target FIXed in test "PMM Cal Sled Test BG200K -15 to 30 psiG Diff" |
CHANGE | CPP-114 | Macros improved for PM200 cal sled calibrations |
ADD | CPP-115 | Add Fluke Calibration 2638A DAQ Support Device to database |
ADD | CPP | Add Fluke Calibration 8270A/8370A as Autodetect Device |
5.0.25 (2016.05.13) | ||
ADD | CPP-74 | The Fluke 2271A is now supported by the Auto-Detect setup function within COMPASS. The instrument can be used as a DUT, Reference and/or to measure the output of an analog or HART DUT connected to the front panel of the instrument. |
ADD | CPP-62 | Manual piston gauges will now use a pressure resolution that is one digit more than the resolution of the active DUT. Changing the Pressure Resolution selection on the Piston Gauge calculator will now cause data to be logged in the selected resolution when running a manual test. Note that the resolution active when the data file is created is used until a new data file is created. |
ADD | CPP-3 | An example setup for the Mensor CPC6000 is now available in the default database. |
ADD | CPP-73 | The serial number of the active PMM is logged in the data file when a Fluke 2271A or 6270A is used as the test pressure reference. The value is available for reports in both the External Serial Number 1,2 fields of the device header and in the Reference Operation column logged for each point in the data file. |
ADD | CPP-54 | A new test macro that provides ISO17025 compliant uncertainty calculations is available in the default database. The macro can be used in an existing Test Definition by ensuring first that the test is setup as an Advanced Test, then selecting the macro "UncCalc" as the Test Event Macro. In [Tools][Options][Data in File] ensure that the columns User Defined 1,2 and string Data 1 are selected for logging to the data file. See the UncCalc test macro for additional details. |
CHANGE | CPP-83 | The front panel pressure unit of legacy Ruska controllers, the Fluke 6270A and the Fluke 2271A will automatically change to inHg when a test is executed in inHg. Previously, the controllers would remain in their current unit of measure and COMPASS would convert and display the pressure in inHg. |
FIX | CPP-85 | Commands sent in a Macro with the ioSendCommand function would never actually be sent to the instrument. The issue is now resolved. |
FIX | CPP-69 | The 2456 PG monitor would not properly updated ambient pressure, temperature and humidity. This issue is now resolved. |
FIX | CPP-72 | The 6270A will no longer generate a front panel error message when setting ATM test points in a pressure exercise or a Test Definition. |
FIX | CPP-77 | The upper and lower limit settings of the 6270A are updated based on the range requirements of the selected DUT and/or Test Definition. |
FIX | CPP-68 | The COMPASS Database Data Viewer can now consistently import and export *.dat files. Previously there were cases in which some files could not be imported or exported properly. |
FIX | CPP-82 | Viewing the Setup picture associated with a Test Definition during Test Initialization would close COMPASS if the picture file type is PNG or a UNC path is selected. An appropriate warning message now displays and incompatible paths and file types are restricted from being used in the Test Definition. |
FIX | CPP-71 | When editing a Test Definition, the Rt-Click option to add an ATM point in the pressure exercise would generate a run-time error in COMPASS. This issue is now resolved and ATM points are fully supported in the pressure exercise. |
FIX | CPP-44 | Using an RPM4 as the ambient pressure source with a Ruska 2465 or 2456 would generate a run time error in COMPASS. This issue is now resolved. |
FIX | CPP-76 | COMPASS 5.0 did not properly support binary RS232 communication. This prevented HART communications from functioning properly. The issue is now resolved. |
FIX | CPP-75 | When creating a set command the label next to the list of set application types now displays "Apply Set". |
FIX | CPP-59 | Resolved a misspelling in the Tools menu. |