- Other Fluke companies:
- Fluke
- Fluke Biomedical
- Fluke Networks
- Fluke Process Instruments
Calibrates surface sensors up to 400°C
Surface probes are difficult to calibrate because it’s hard to find a flat, heated surface that’s stable and uniform. The model 3125 Surface Dry-Well takes advantage of our proprietary 2200 Temperature Controller and gives you the best possible conditions for calibrating surface sensors.
Why buy a non-temperature calibration device designed for test tube sterilization or PC board repair when you can have a true calibration instrument? The 3125 has a uniform surface temperature and reaches temperatures as high as 400°C.
The test surface is milled aluminum for an absolutely smooth and true calibration work area with maximum thermal conductivity. The 12.25-square-inch test surface is large enough to calibrate more than one sensor at a time. The 3125 can be used with a reference surface sensor or PRT. PRTs (3/16" diameter, such as the 5615) may be inserted through a drilled hole into the center of the block for use as reference thermometers or for easy recalibration of the unit’s display.
With an accuracy of ±0.5 °C to 200 °C and ±1 °C to 400 °C, you can calibrate almost any surface probe, thermistor, thin film sensor, RTD, thermocouple, ribbon sensor, or surface mount cutouts, fuses, and switches. Stability is within ±0.3 °C at 400 °C and uniformity within the center three inches of the surface is ±0.6 °C at 200 °C. Don’t buy “make-do" hot plates when you can have a legitimate calibration tool.
Specifications | |
Temperature Range | 35 °C to 400 °C (95 °F to 752 °F) |
Display Accuracy | ±0.5 °C to 200 °C ±1.0 °C to 400 °C |
Stability | ±0.2 °C to 300 °C ±0.3 °C to 400 °C |
Resolution | 0.01 ° |
Uniformity | ±0.3 °C at 100 °C ±0.6 °C at 200 °C ±0.9 °C at 300 °C ±1.4 °C at 400 °C |
Heating Time | 25 °C to 400 °C: 22 minutes |
Cooling Time | 400 °C to 100 °C: 65 minutes |
Stabilization Time | 8 minutes |
Controller | Fluke Calibration Model 2200, microprocessor based, with RS-232 |
Readout | °C or °F, switchable |
Sensor | RTD, 100Ω |
Heater | 325-watt, solid-state controlled |
Surface Plate | 6061 aluminum; top surface machine finished to 0.0008 mm (0.000032 in), 96 mm (3.8 in) diameter accessible |
Power | 115 VAC (±10 %), 2.8 A or 230 VAC (±10 %), 1.4 A, specify, 50/60 Hz, 325 W |
Weight | 3.2 kg (7 lb.) with 2200 Controller |
NIST-Traceable Calibration | Data at 50 °C, 120 °C, 190 °C, 260 °C, 330 °C, and 400 °C |
Model Name | Description |
---|---|
3125 |
Surface Calibrator (includes detachable Model 2200 Controller) |
Accessories common to all models:
Accessory | Description |
---|---|
HART DRYWELL CABLE |
An interface cable kit that includes a null modem to connect the Fluke 754 with Fluke Calibration dry-wells and Micro-Baths to automate and document the calibration of temperature sensors and transmitters in the field or at the bench. |
- Home
- Products
- New Products
- Electrical Calibration
- RF Calibration
- Data Acquisition and Test Equipment
- Temperature Calibration
- Humidity Calibration
- Pressure Calibration
- Flow Calibration
- Process Calibration Tools
- Calibration Software
- Service and Support
- All Calibration Instruments
- Purchase Info
- News
- Training and Events
- Literature and Education
- Service and Support
- About Us
Sidebar Request a Quote
Request a quote