- Other Fluke companies:
- Fluke
- Fluke Biomedical
- Fluke Networks
- Fluke Process Instruments
Thermocouple Calibrators
Whether you're simulating thermocouples or calibrating thermocouples directly through comparison methods, Fluke offers the most comprehensive selection of quality thermocouple calibrators on the market, including thermocouple simulators, handheld multifunction calibrators, temperature sources such as dry-block calibrators and liquid baths, thermocouple reference Standards, and thermocouple readouts.
Thermocouple calibration product catagories include:
- Handheld thermocouple calibrators and simulators
- Comparison calibration instruments
Handheld Thermocouple Calibrators and Simulators
These handheld products are used for calibration of thermocouple indicators and thermocouple measurement devices such as temperature transmitters.
Model | Range | Thermocouple Type | Description/Features |
754 Documenting Process Calibrator-HART |
-250 to 2500 °C | E, N, J, K, T, B, R, S, C, L, U, BP, XK | Documenting calibrator with HART, TC and RTD temperature calibrator, with loop power, source/measure TC and measures mA |
7526A Precision Process Calibrator | –250 °C to 1767 °C | B, C, E, J, K, L, N, R, S, T, U, XK, BP | Offers the best balance of economy and accuracy for benchtop calibration of temperature and pressure process instrumentation |
726 Precision Multifunction Calibrator | -200 to 1800 °C | J, K, T, E, L, N, U, C, BP, XK, B, R, S | Multifunction calibrator (twice as accurate as 725) |
725 Multifunction Process Calibrator | -200 to 1800 °C | J, K, T, E, R, S, B, L, U, N | Multifunction calibrator, TC and RTD temperature calibrator, with loop power, source/measure TC and measures mA |
724 Temperature Calibrator | –200 to 1800 °C | J, K, T, E, R, S, B, L, U | TC and RTD temperature calibrator, with loop power, source/measure TC and measures mA |
714B Thermocouple Calibrator | -250 to 1410 °C | E, N, J, K, T, B, R, S, C, L, U, BP, XK, G, D, P, M | Thermocouple (TC) temperature calibrator, source/measure TC and measures mA |
Comparison Calibration Instruments
Calibration of a thermocouple by comparison methods requires:
- Reference thermometer
- Thermometer readout
- Stable and uniform temperature source
Fluke offers a wide range of products to fit your temperature range, accuracy, and budget requirements.
Reference Thermometers
Model |
Range |
Accuracy |
Description/Features |
0 °C to 1450 °C |
greater of ±0.6°C or ±0.1% of reading |
Eight models to fit any ype R or S thermocouple application |
|
0 °C to 1000 °C |
± 0.006 °C at 0 °C ± 0.031 °C at 660 °C ± 0.041 °C at 961 °C |
World’s finest high-temperature secondary PRT |
|
–200 °C to 661 °C |
± 0.006 °C at –200 °C ± 0.006 °C at 0 °C ± 0.015 °C at 420 °C ± 0.022 °C at 661 °C |
Fills the gap between affordable, but temperature-limited secondary PRTs and more expensive, highly accurate SPRTs |
|
–200 °C to 670 °C |
± 0.007 °C at –200 °C ± 0.008 °C at 0 °C ± 0.020 °C at 420 °C ± 0.027 °C at 660 °C |
Very stable thermometer |
Thermometer Readouts
Model |
Range |
Accuracy |
Description |
-15 mV to 100 mV |
0.004 % + 4 µV |
Most accurate and flexible temperature data acquisition system on the market |
|
-10 to 100 mV |
± 0.002 mV |
Accurate, expandable and configurable readout |
|
-10 mV to 100 mV |
± 0.005 mV |
Lab-quality accuracy on four channels |
|
0 Ω to 400 Ω ± (0.004 % + 0.002 Ω) 200 Ω to 50 kΩ± (0.01 % + 0.5 Ω) 50 kΩ to 500 kΩ± (0.03 %) |
Measure, graph and record three sensor types with one tool |
Thermocouple Calibration Furnaces
Model |
Range |
Stability |
Description/Features |
300 °C to 1200 °C |
± 0.2 °C (without block), ± 0.1 °C (with block) |
Horizontal thermocouple furnace. Flexible configuration for calibrating thermocouple bundles, spools, and sheathed thermocouples. |
|
150 °C to 1200 °C 302 °F to 2192 °F |
±0.5 °C |
Benchtop thermocouple furnace. Interchangeable insert sleeves. Fast heating and cooling. |
Dry-Block Calibrators
Model |
Range |
Accuracy |
Description/Features |
–25 °C to 150 °C |
± 0.2 °C |
Light-weight portable and fast Reads and documents °C, mV, W, and 4-20 mA 24 volt loop power Includes accredited certificate of calibration |
|
33 °C to 350 °C |
± 0.2 °C |
||
50 °C to 660 °C |
± 0.35 °C at 50 °C ± 0.35 °C at 420 °C ± 0.5 °C at 660 °C |
||
–95 °C to 140 °C |
Accuracy: ± 0.2 °C |
Horizontal thermocouple furnace. Flexible configuration for calibrating thermocouple bundles, spools, and sheathed thermocouples. |
Liquid Baths
Model |
Range |
Stability |
Depth |
Description/Features |
35 °C to 250 °C |
0.015 °C |
400 mm (15.7 in) |
Four times more calibration throughput and twice the accuracy of Micro-Baths and dry-block calibrators |
|
–25 °C to 140 °C (–15 °C cover off) |
0.01 °C |
400 mm (15.7 in) |
Four times more calibration throughput and twice the accuracy of Micro-Baths and dry-block calibrators |
|
35 °C to 300 °C |
±0.005 °C at 100 °C ±0.015 °C at 300 °C |
234 mm (9.25 in) |
Small benchtop footprint. Optional cart includes storage space. High temperature bath |
|
–20 °C to 150 °C |
±0.005 °C at –20 °C ±0.005 °C at 25 °C |
234 mm (9.25 in) |
Small 9.2-liter (2.4-gallon) tank. Uniformity ±0.005 °C. |
|
–40 °C to 150 °C |
±0.005 °C at –40 °C ±0.005 °C at 25 °C |
234 mm (9.25 in) |
Low temperature calibrations. Metrology-level performance. |
|
–80 °C to 100 °C |
±0.006 °C at –80 °C ±0.010 °C at 0 °C |
178 mm (7 in) |
Achieves –80 °C in less than 130 minutes. Quiet operation. |
|
40 °C to 300 °C |
±0.007 °C at 100 °C ±0.015 °C at 300 °C |
457 mm (18 in ) |
18 in of depth with just 16 liters of fluid. RS-232 included. |
|
–20 °C to 150 °C |
±0.005 °C at –20 °C ±0.005 °C at 25 °C |
457 mm (18 in) |
Perfect for LIG thermometers with optional kit. Quiet operation. |
|
–45 °C to 150 °C |
±0.005 °C at –40 °C ±0.005 °C at 25 °C |
457 mm (18 in) |
Fast temperature changes. Access opening accommodates many thermometers. |
|
–80 °C to 110 °C |
±0.006 °C at –80 °C ±0.005 °C at 0 °C |
457 mm (18 in) |
Stability of ±0.006 °C or better over full range. Compatible with MET/TEMP II software. Low temperature bath |
Calibration Bath Accessories
Stands, rods, and clamps to suspend and support your probes and thermometers |
|
Silicone oils, salt, and cold fluids in convenient, small quantities. |
Related Selection Guides
- Thermometer Probe Selection Guide
- Thermometer Readout Selection Guide
- Probe-to-Readout Adapter Guide
- Data Acquisition System Selection Guide
Get help
If you are interested in learning more about how to calib rate a thermocouple, see the Fluke Calibration Thermocouple Application Note Series or register for the Fluke Calibration Practical Temperature Calibration course.
Need help selecting a thermocouple calibrator? Speak with one of our thermocouple calibrator equipment experts.
- Home
- Products
- New Products
- Electrical Calibration
- RF Calibration
- Data Acquisition and Test Equipment
- Temperature Calibration
- Humidity Calibration
- Pressure Calibration
- Flow Calibration
- Process Calibration Tools
- Calibration Software
- Service and Support
- All Calibration Instruments
- Purchase Info
- News
- Training and Events
- Literature and Education
- Service and Support
- About Us
Sidebar Request a Quote
Request a quote