- Other Fluke companies:
- Fluke
- Fluke Biomedical
- Fluke Networks
- Fluke Process Instruments
Chill to –40, –60, or –80 °C without external coolants
- Self-contained refrigeration—no LN2 or chiller required
- Temperatures as low as –80 °C in real metrology baths
- Best stability and uniformity available at –80 °C and below
- Large working areas for increased throughput
Find a refrigerated calibration bath for extremely low temperatures (i.e. –80 °C). Fluke Calibration metrology baths are well known world-wide for excellent temperature control that maintains excellent temperature, stability (±0.0015 °C) and uniformity (±0.003 °C). Models 7060 and 7080 can be used with Fluke Calibration bath fluids to reach extremely cold temperatures.
Do you need a bath that chills below –40 °C to temperatures as low as –60 °C or even –80 °C? Would you like a bath that reaches those temperatures without using any external coolants? Fluke Calibration the baths that meet these temperature requirements and give you the best stability in the industry.
These baths are completely self-contained. They require no auxiliary cooling fluids or devices to achieve their set-point temperatures. Using Fluke Calibration's unique "heat-port" design, stability at –80 °C is ±0.0025 °C. No other company makes a bath that can match a Fluke Calibration bath’s performance, and Fluke Calibration baths are backed by our guarantee that if they don’t perform exactly the way we say they will, we’ll take them back. No arguments. No ifs, ands, or buts.
If you want to completely automate the entire calibration process, see the description of Fluke Calibration's MET/TEMP II software package.
Forget commodity-like utility baths! They’re not designed for high performance calibration needs. And be careful of companies that advertise performance specifications they don’t meet. It’s easy to write down numbers; it’s more difficult to meet them with an instrument.
Remember, if our baths don’t perform the way we say they will, just send them back. Our equipment won’t disappoint you.
Specifications |
7060 |
7080 |
Range | −60 °C to 110 °C | −80 °C to 110 °C |
Stability | ±0.0025 °C at −60 °C (methanol) ±0.002 °C at 0 °C (methanol) ±0.0015 °C at 25 °C (water) ±0.003 °C at 100 °C (oil 5012) |
±0.0025 °C at −80 °C (methanol) ±0.0015 °C at 0 °C (methanol) ±0.0015 °C at 25 °C (water) ±0.003 °C at 100 °C (oil 5012) |
Uniformity | ±0.005 °C at −60 °C (methanol) ±0.005 °C at 0 °C (methanol) ±0.003 °C at 25 °C (water) ±0.005 °C at 100 °C (oil 5012) |
±0.007 °C at −80 °C (methanol) ±0.005 °C at 0 °C (methanol) ±0.003 °C at 25 °C (water) ±0.005 °C at 100 °C (oil 5012) |
Temperature Setting | Digital display with push-button data entry | |
Set-Point Resolution | 0.01 °C; high-resolution mode, 0.00007 °C | |
Display Resolution | 0.01 °C | |
Digital Setting Accuracy | ±1 °C |
|
Digital Setting Repeatability | ±0.01 °C |
|
Heaters | 500 and 1000 Watts | |
Access Opening | 127 x 254 mm (5 x 10 in) | |
Depth | 305 mm (12 in) | |
Wetted Parts | 304 stainless steel | |
Power | 230 VAC (±10 %), 50 or 60 Hz, 13 A, single phase, specify frequency | |
Volume | 27 liters (7.2 gallons) | |
Weight | 159 kg (350 lb.) | |
Size (HxWxD) |
1168 x 775 x 483 mm (46 x 30.5 x 19 in) |
|
Automation |
Use the 1586A Super-DAQ to automate temperature sensor calibration |
Model Name | Description |
---|---|
7060 |
Standard Bath, –60 °C to 110 °C |
7080 |
Standard Bath, –80 °C to 110 °C |
Accessories common to all models:
Accessory | Description |
---|---|
Calibration Bath Fluids | |
2010 |
Access Cover, 127 x 254 mm (5 x 10 in), Lexan |
2007 |
Access Cover, 127 x 254 mm (5 x 10 in), Stainless Steel |
2001-IEEE |
IEEE-488 Interface, 6330/7320/7340 |
2069 |
Magnifying Scope for Liquid-in-Glass Thermometer Calibration |
2016-7080 |
Fluid Level Adapter, 7080 |
2016-7060 |
Fluid Level Adapter, 7060 |
2016-7060 |
Fluid Level Adapter, 7060 |
2620 |
RTD Probe, 280 mm (11 in.) |
Product Manuals |
---|
Application Notes |
---|
Buying the right temperature calibration bath for your laboratory |
Why a Fluke calibration bath? |
Papers / Articles |
---|
Fluke Calibration Bath Safety Features |
How to Choose a Calibration Bath |
On-Demand Webinars |
---|
How to Select the Right Temperature Calibration Bath |
- Home
- Products
- New Products
- Electrical Calibration
- RF Calibration
- Data Acquisition and Test Equipment
- Temperature Calibration
- Humidity Calibration
- Pressure Calibration
- Flow Calibration
- Process Calibration Tools
- Calibration Software
- Service and Support
- All Calibration Instruments
- Purchase Info
- News
- Training and Events
- Literature and Education
- Service and Support
- About Us
Sidebar Request a Quote
Request a quote